CHEMICAL PROBLEMS, vol.3, pp.465-469, 2019 (Peer-Reviewed Journal)
The influence of synergetic mixtures of inhibitors based on inorganic oxidants and monoethanolamine (MEA) on contact corrosion of steel St-3 coupled with copper and latten was explored by
means of electrochemical and gravimetric methods. It revealed that insertion of synergetic mixtures into the fresh water used in the cooling systems reduces the corrosion current nearly to one
range.